Service Hotline:  (  +86)400-168-0023
Products Products
Product name:

Electrical Safety and Prevention Comprehensive Device---ENRELY

Listing date: 2017-06-23

ENRELY is a security combination solution for the electrical system. With ENRELY, customers benefit from markedly reduced costs and safety of the electrical system and environment . Thanks to flexible applications and multifunction that means a package solution of the whole system takes ground potential attack suppressing, fault arc warning, three-phase unbalance adjustment , reactive power optimization,harmonic filtering and low voltage control, and significantly reduce the consumption of transformer, line loss, suppress over-voltage induced by resonance/operator and lightning and alleviate the insulation aging etc. 


ENRELY can be installed or expanded in any location, at any time, regardless of whether or there is not already a LPS or other safety system installed. ENRELY fault self-diagnosis function, can effectively detect the faults which exist in the whole equipment or system, the testing results and relevant data are timely reported through the temperature sensor ,light display and remote communication.


At the same time , ENRELY’s BYPASS switch will make the faulty equipment timely turn off , in order to ensure the normal operation of the whole system. ENRELY can significantly reduce serious accidents such as the fire and explosion, overheating , short circuit and over-voltage caused by the overload . strengthen the safety of the power supply and distribution.So that ENRELY is widely used in power station industry , new energy industry , petrochemical industry , automobile manufacturing industry and transportation industry etc.

ANTI-GROUND POTENTIAL ATTACK when the direct lightning occurs , the lightning rod or lightning network connected , the powerful lightning will take a path to ground , when over voltage in the high voltage line caused by induction lightning attacked , the lightning current flows into ground through the LPS , when the running equipment interrupted by the strong interference from the electric welding machine , and the disturbance current will also flow into the ground . the strong current from ground will make data loss , equipment malfunction , equipment tripping , insulation damage or burnout , when lightning strikes the high voltage line, the strong lightning current flows into the ground through LPS . 


The ground potential is transiently raised a lot, and the lightning current makes a huge voltage drop on the low voltage winding , then back to the primary winding , resulting in the transformer damaged by high voltage. If the ground takes 100kv, the voltage on the secondary winding will produce 25kv . to get the primary winding voltage increasing to 625KV, the transformer insulation tier will be broken down .


 With ENRELY COMPREHENSIVE INTEGRATED DEFENSE SOLUTION, it hampers the path of the lightning current into the secondary winding , so that all of lightning current and other strong disturbance current mostly flows into the ground to ensure safety of the transformer and the secondary equipment.


1 The fault arc warning 

Arc fault is the main reason causing electrical fire accident.

ENRELY device with two our-own patents , which can accurately detects system fault arc for fire warning and system protection to reduce the fire accident.


Features

1, effective running on the circuit of grounding arc, parallel arc and series arc.

2, Excellent dynamics :fast detection time is less than 200ms

3, dynamic detection accurately

4,transit signal to control action of output switch.

5, Alarming with sound and light display

6,complete communication protocol according to individual equipment


2 Adjustment of imbalance in the three-phase


Features

Major hazards of imbalance in three-phase unbalance:

1, increase the power loss of line and transformer

2. Increase the iron loss of  transformer

3. overload in single phase reduces the output of distribution transformer

4, reducing efficiency of motor.

5, increasing risk of power equipment operation

6, reducing the quality of power

7, affect energy metering


3 reactive power optimization


Product advantage:

1, sufficient compensation

2, over- compensation non existed

3, stepless continuous smooth adjustment

4. Reactive power and power factor can be set by yourself

5, the response time is faster (less than 5ms)

6, when low voltage, it has strong voltage support ability


Features

1, it will be compatible with original capacitor

2, capacitor runs by step-switch

3, ENRELY covers blind spots

4, over compensation does not exist

5, suppress the resonance of the system

Hot Products / Related Products More
2017 - 06 - 23
ENRELY is a security combination solution for the electrical system. With ENRELY, customers benefit from markedly reduced costs and safety of the electrical system and environment . Thanks to flexible applications and multifunction that means a package solution of the whole system takes ground potential attack suppressing, fault arc warning, three-phase unbalance adjustment , reactive power optimi...
2017 - 11 - 23
GPAS (Ground Potential Attack Suppressor) is an active lightning protection device that combines ground potential attack suppression and fault arc defense. It can significantly reduce lightning damage, Arc damage and destruction of the equipment through suppress the ground potential counter-attack .The fact of lightning – It must be respected at all times, not just during the peak periods of ...
2017 - 06 - 23
What to expect with GreenSine?BENEFITS:There are several benefits of reducing harmonics and disturbances in the electrical network.1 optimize your network , lower network utilization (stability , compensate power)2 Lower losses in the transformer, decrease power consumption and noise 3 Prolonged equipment lifetime with harmonic mitigation.4 Avoid non-compliance with electrical standard 5...
2017 - 06 - 22
WHAT IS STATIC VAR GENERATOR?The principle of SVG: When the load is generating inductive or capacitive current , it makes load current lagging or leading the voltage . SVG detects the phase angle difference and generates leading or lagging current into the grid , making the phase angle of current almost the same as that of voltage on the transformer side .which means fundamental power factor is un...
Copyright © 20017 - 2019 Enrely
犀牛云提供企业云服务
犀牛云提供云计算服务
Address:Room 1208,North Fourth Ring Mid-way Haitai Building,Haidian District,Beijing,China

Telphone:+86 0755-2955 6666
Fax:+86 0755-2788 8009
Zip code:330520