Product name:

Ground Potential Attack Suppressor---GPAS

Listing date: 2017-11-23

GPAS (Ground Potential Attack Suppressor) is an active lightning protection device that combines ground potential attack suppression and fault arc defense. It can significantly reduce lightning damage, Arc damage and destruction of the equipment through suppress the ground potential counter-attack .


The fact of lightning 

– It must be respected at all times, not just during the peak periods of a thunderstorm.

– It is the result of high voltage currents.

– It is unpredictable. This makes researching natural organic strikes very hard.

– Most characteristics of lightning are intelligent estimates of typical values formed from other data.

– A properly installed lightning protection system will help to protect a property or structure from lightning damage. The Empire State Building is proof of this.


GPAS has fault self-diagnosis function, which can effectively monitor the fault of the system and equipment, and timely report result through the temperature sensor, indicator light display and remote communication; meanwhile, timely switching the equipment through the bypass switch function in order to ensure the normal operation of system.


GPAS is utmost reliability and realizing that it can effectively isolate the high-frequency lightning current in shorter operation time to prevent invasion of the ground network by lightning current flowing ;At the same time , it tests accurately the fault arc, and then disconnect the circuit breaker to avoid accidents of Fire, explosion etc.


Ground potential attack

The major of electronics damage from lightning strikes. The most damages is not caused by direct lightning strikes, but is the result of Ground potential attack, When a lightning strike directly on a building or facility with LPS(lightning protection system includes lightning rods, metal conductors and ground grid ) , the ground potential can be raised to thousands of volts during  microseconds. The lightning currents from the various parts of the ground to the power supply system and a variety of network signaling systems,in order to attack and destroy electronic equipment. This attack will expand the damage of large-scale equipment in the form of electromagnetic wave along the Neutral line and the ground point.


In the meantime, there is a risk that sparks may be induced at high potentials in non-bonding lead circuits with equal potential. When the ground potential attacks make the grounding of each device to have high potential at the same time. If the device is not connected to ground or the grounding of equipment is not good, As result , not only the device will get breakdown, but also the equipment operator will be hit by electric shock!


Arc fault

When lightning strikes, the ground potential often causing arc fault with high power, high temperature and high rapid diffusion.Its maximum power up to millions of kilowatts, arc temperature up to 2000 degrees 


Under the action of strong airflow and electric field, the high temperature and heat generated by the fault arc leads to the insulation tier of line. If there is the combustible material near the fault point, it can easily ignite the combustibles Which led to fire accident .


Electric arc disturbance

Arc welding is the most widely used welding method in industrial production.the principle of Arc welding is that utilizing low voltage and high current to generate arc for continuous power supply and melting the metal for welding. the temperature up to 5000 ~ 8000 ℃, bipolar temperature up to 3500 ~ 4200 ℃.


Arc welding will produce a large number of arc current flowing into the network, when the lack of ground grid protection, the arc current flows into other production plants in order to  equipment damage; At the same time, operator often drag and drop the electric welding wire during welding, easily damage the insulation to cause a short circuit, resulting in fire or casualties accident.


WHAT YOU EXPECT WITH GPAS?


Function :

1 GPAS barrier the lightning current to flow into the secondary winding path of transformer, so that to utmost all the lightning current or other strong interference current flows into the grounding grid, protect the transformer and secondary equipment and keep the electrical system safe.


2GPAS can accurately and quickly detect the fault arc in the system, early-fire warning and protection and greatly reduce the fire accident.

Features:

1, Effective work in circuit of the grounding,series and parallel arcing series and parallel arcing 


2, fast detection time: ≦ 200ms


3, dynamic detection accurately


4, transit signal to control action of output switch.


5, Alarming with sound and light display


6, complete communication protocol according to individual equipment

 

BENEFITS

1, low cost and simple installation

Compared with the traditional grounding method that needs chemical products such as a resistance reducing agent and a grounding rod to reduce LPS(lightning protection system) resistance. GPAS protects the equipment through connection with a lightning protection bar and a protection grounding bar, and also can be installed on a stick outdoors or mounted on Wall indoors.

 

2, GPAS does not affect running of monitoring system of anti-fire and LP.

Due to increasing of the lightning current power, high impedance appears in device ,GPAS can interrupt the lightning strike back, and make the lightning current flow into the ground; when power of the lightning current discharges completely,then the device returns to low impedance state to ensure LPS safe. Automatically GPAS suppress parts of the lightning current flowing into other line branch does not affect running of monitoring system of anti-fire and LP. 

 

3, GPAS heightens the safety of equipment by lighting-attacked in the way of diverting over-voltage from lightning.

GPAS gains the functions of the lightning over-voltage divert and high-frequency isolation, through in connection with equal potential ground to eliminate the potential difference between equipment to avoid equipment damage caused by high potential difference.

 

4, GPAS detects fault arc automatically, to avoid serious damage.

GPAS effectively detects the arc and electrospark caused by ground potential attack arc fault, electrical components poor contact, and grounding fault etc; when the arc occurs,GPAS alarms with  the sound and light display,at the same time ,it sends the signal to the output breaker to make circuit open to avoid serious damage of switch gear.

Hot Products / Related Products More
2017 - 06 - 23
ENRELY is a security combination solution for the electrical system. With ENRELY, customers benefit from markedly reduced costs and safety of the electrical system and environment . Thanks to flexible applications and multifunction that means a package solution of the whole system takes ground potential attack suppressing, fault arc warning, three-phase unbalance adjustment , reactive power optimi...
2017 - 11 - 23
GPAS (Ground Potential Attack Suppressor) is an active lightning protection device that combines ground potential attack suppression and fault arc defense. It can significantly reduce lightning damage, Arc damage and destruction of the equipment through suppress the ground potential counter-attack .The fact of lightning – It must be respected at all times, not just during the peak periods of ...
2017 - 06 - 23
What to expect with GreenSine?BENEFITS:There are several benefits of reducing harmonics and disturbances in the electrical network.1 optimize your network , lower network utilization (stability , compensate power)2 Lower losses in the transformer, decrease power consumption and noise 3 Prolonged equipment lifetime with harmonic mitigation.4 Avoid non-compliance with electrical standard 5...
2017 - 06 - 22
WHAT IS STATIC VAR GENERATOR?The principle of SVG: When the load is generating inductive or capacitive current , it makes load current lagging or leading the voltage . SVG detects the phase angle difference and generates leading or lagging current into the grid , making the phase angle of current almost the same as that of voltage on the transformer side .which means fundamental power factor is un...